| SPECTRUM 'WAM' WIRELESS MONITOR SYSTEMS |
Spectrum Instruments' family of "WAM" advanced wireless monitoring systems support a wide variety of analog inputs. WAM models are capable of acquiring 6/7/56 vibration channels containing frequencies from DC up to 20 KHz. Data from 6 to 56 additional channels of process variables can also be acquired. Low resolution sensors such as cold junction thermocouples are amplified with an internal temperature compensation board supporting both J and K type thermocouples. Vibration data is acquired simultaneously in groups of three(3), seven(7) or fifty six(56) channels depending on the model selected.
.  |
KEY FEATURES
- 6, 7 or up to 56 vibration inputs with frequency ranges from near DC up to 40 KHz sample rate
- accepts accelerometer & piezovelocity sensors, proximity probes, 4-20 ma process signals and more
- data from 6 or 56 process channels can also be acquired
- available on-board amplification available for low level signals such as thermocouples
- 1 Tachometer input is provided in addition to the 6 measurement channels
- 900 MHz radios provide broadcast range of up to 2 miles
- WLAN radios and Ethernet for high speed connectivity is also available on some models
- On-board sample memory allows 2 million samples at rates from 64 to 20 KHz
- On-board conditioning circuitry with programmable high /low pass filtering
- Analog integration for acceleration to velocity
- Water and weatherproof housing meets IP67 standards
|
For vibration configured channels, a standard 20V/4ma current is provided for biasing accelerometers. This bias voltage can be disabled to allow direct AC inputs from other devices such as proximity probes.
The Spectrum WAM wireless monitoring system communicates back to the base station via a long range Spread Spectrum 900 MHz radio. An optional WLAN communication (802.11B or 802.11G) is available for higher speed, shorter range applications. Ethernet connectivity is offered on the 35 input model.
Wireless data is managed by Pathfinder Software Suite; Pathfinder software receives and manages incoming data from multiple Spectrum WAM ’s, performs an open-architecture archiving function, generates operator interface bar graphs, and provides advanced analytical tools such as windows for FFTs, waterfalls, orbits, trends, real time waveforms as well as Bode and Nyquist plots.
RESOLVING DATA BASE CONTINUITY ISSUES
Are you currently operating a vibration based predictive maintenance program using:
a SKF system ? Rockwell ? CSI ? Technekon ?
or any other brand name data collector system ?
Spectrum Instruments' optional "TRANSLATOR" software allows vibration data captured by its WAM field module and stored in the Pathfinder Software Suite to be transferred to ANY brand name data collector for downloaiding / archiving into a plant's existing vibration based PM software program. This allows the customer to analyze machine data captured by Spectum's WAM system with his own PM software that he is familiar with while at the same time, embedding new data supplementing existing historical data for improved condition trending. Our "TRANSLATOR" software means no new software to learn! |
SPECIFICATION
|
| |
| |
WAM 661 |
WAM 761 |
WAM 56U |
| INPUT CAPACITY |
| VIBRATION CHANNELS (MAX) |
6
|
7
|
56
|
PROCESS CHANNELS (MAX)
(T/C's, V, I, Strain + more) |
6
|
6
|
56
|
| TACH CHANNELS |
1
|
1
|
1
|
| WIRELESS COMMUNICATION |
| RADIO FREQUENCY |
900 Mhz ISM
|
900 Mhz ISM AND 802.11
|
900 Mhz ISM
AND 802.11
|
| MESH NETWORK |
NONE
|
65,536 MODULES
AUTO CONFIG; 8 HOPS |
NONE
|
| ETHERNET |
NO |
NO |
YES |
| PERFORMANCE |
| MEMORY |
512K SAMPLES - SINGLE CHANNEL, UP TO 128k SAMPLES FOR 4 CHANNELS |
1 MEG SAMPLES - SINGLE CHANNEL, UP TO 128k SAMPLES FOR 8 CHANNELS |
1 MEG SAMPLES - SINGLE CHANNEL, UP TO 128k SAMPLES FOR 8 CH SIMULATANEOUS |
| TRANSIENT CAPTURE |
IMMEDIATE SAMPLING |
RAMP UP / RAMP DOWN
BASED ON TACH |
RAMP UP / RAMP DOWN
BASED ON TACH |
| TRANSIENT CAPTURE DURATION |
25 SEC @ 1.25 KHz
SAMPLE RATE,
SINGLE CHANNEL |
820 SEC @ 1.25 KHz
SAMPLE RATE,
SINGLE CHANNEL |
820 SEC @ 1.25 KHz
SAMPLE RATE,
SINGLE CHANNEL |
| SPECTRAL |
3-CHANNEL
SIMULTANEOUS
SAMPLING |
7-CHANNEL
SIMULTANEOUS
SAMPLING |
35-CHANNEL
SIMULTANEOUS
SAMPLING |
| FFT RESOLUTION |
64K POINTS |
64K POINTS |
64K POINTS |
| ANALOG SIGNAL CONDITIONING |
4TH ORDER FILTER
20 BIT A/D 40 KHz
SAMPLE RATE |
4TH ORDER FILTER
20 BIT A/D 40 KHz
SAMPLE RATE |
4TH ORDER FILTER
20 BIT A/D 40 KHz
SAMPLE RATE |
| FREQUENCY RANGE |
10 Hz - 10 KHz |
DC/1 Hz - 120 KHz |
DC/1 Hz - 120 KHz |
| TRIGGERS |
NONE |
TRIGGER ON TACH |
TRIGGER ON TACH |
| TRANSLATOR DATA COLLECTOR INTERFACE |
OPTIONAL |
OPTIONAL |
OPTIONAL |
| MECHANICAL / ENVIRONMENTAL |
| CONNECTIONS |
RPSMA FOR ANTENNA
BNC FOR INPUTS |
RPSMA FOR ANTENNA
BNC FOR INPUTS |
RPSMA FOR ANTENNA
BNC FOR INPUTS |
| ENCLOSURE |
ANODIZED ALUMINIUM
WATERPROOF |
ANODIZED ALUMINIUM
WATERPROOF |
NEMA ENCLOSURE |
| OPERATING TEMPERATURE |
-40 TO 85 DEG C |
-40 TO 85 DEG C |
-40 TO 85 DEG C |
| ELECTRICAL |
| POWER REQUIREMENTS |
24 VDC / 200 MA |
24 VDC / 200 MA |
24 VDC / 400 MA |
Click here to take our interactive 'WAM' TOUR Click here for a copy of our latest 'WAM' BROCHURE
|
AVAILABLE WAM ACCESSORIES |
Cost effective top-connector accelerometer - WAM-80B
Cost effective side-connector accelerometer - WAM-85A 
Premium side-connecotor accelerometer - WAM97 
Thermocouple & RTD Sensors - WAMTT 
Explosion proof speed sensor - WAM-T3070
Ethernet Bridge
|